Telect MIX 56 Network Card User Manual


 
MIX 56 User Manual 1 Descriptions
122188-10 A0 Telect, Inc.
1-7
Ethernet Port: One per system. RJ-45 10Base-T (half-duplex) connector
with two LEDs. Interface for managing system remotely via either SNMP
or Telnet. When lit, green LED means valid link pulse detected and flash-
ing yellow LED means traffic in either direction.
NOTE
Before using the Ethernet port, you must connect to the local craft interface
through the Craft port and set the system’s IP and Subnet Mask addresses
in the System Interfaces screen. See “Specifying System Interface Settings”
on page 4-17.
Power Receptacle: One per system (20Vdc to 60Vdc). Four-position con-
nector (14-22 AWG) used to supply redundant (A, B) power to the system.
The power connector may be a wire-clamping, screw-type terminal or a
two-piece mated connector.
Logic and Coaxial Shield Ground: One per system. Three-position DIP
switch. Used to connect logic ground, DS3 shield TX ground, and DS3
shield RX ground to chassis ground:
on = connected to chassis ground
off = disconnected from chassis ground
M13 Card
Dimensions
Width = .06 in.
(.16 cm)
4.75 in.
(12.07 cm)
9.60 in.
(24.38 cm)
LED Status
Indicator
Part # 747-1001-0000