122188-10 A0 Telect, Inc. 4-1
4 Software Operation
MANAGING A SYSTEM
You can configure, test, and monitor a system using these interfaces:
• Via Ethernet Port located on rear of chassis (one per system):
◊ SNMP (Simple Network Management Protocol) Interface
◊ Craft Interface over Telnet connection (up to two Telnet sessions)
◊ TL1 Interface over Telnet connection (up to two Telnet sessions)
• Via Craft Port (serial port) on front of chassis (one per system):
◊ Craft Interface over RS232 serial connection
◊ TL1 Interface over RS232 serial connection
• Via Remote Control:
If the MIX 56 is connected over the DS3 link to another MIX 56 and
they are both in C-bit mode on the DS3 link, then a remote control ses-
sion can be run where the user is controlling the MIX 56 at the remote
end of the DS3 link.
◊ Craft Interface over DS3 Link
◊ TL1 Interface over DS3 Link
ALERT
!
ALERT! It is possible to have multiple active sessions at the
same time involved in configuring the same system. It is possi-
ble to have five active sessions at the same time: one via the
serial port; two via Telnet connections; one SNMP; and one via
Remote Control.