Telect MIX 56 Network Card User Manual


 
4 Software Operation MIX 56 User Manual
4-20 Telect, Inc. 122188-10 A0
Step Action
1. From the Directory screen, press 6 to select High Speed Configura-
tion, then Enter.
The High Speed Configuration screen appears.
2. In the Name field, type a name for the DS3 circuit (up to 16 charac-
ters) and press Enter.
3. Tab to the Clock Source field, select a clock source by pressing the
spacebar to toggle between DS3 Loop Timing and Internal, and
then press Enter.
DS3 Loop Timing—Timing is recovered from the incoming
DS3 signal.
Internal—Timing is generated by the onboard Stratum 4 clock.
NOTE
In DS3 networks, one network element provides master timing,
while the other one recovers timing from the incoming DS3 signal.
4. Tab to the Mode field, select a DS3 mode by pressing the spacebar
to toggle between M13 and C-bit, and then press Enter.
MIX 56 by Telect MIX 56 Directory (Ctrl+D)
Help (?)
High Speed Configuration
------------------------
Name: High Speed
Clock Source: DS3 Loop Timing
Mode: M13
Optional C-bit LAPD Information
-------------------------------
Local Remote
--------------------------------- -------------------------------
Equipment ID:
Location ID:
Frame ID:
Unit ID:
Facility ID - Local:
Facility ID - Remote:
[Apply]