MIX 56 User Manual 4 Software Operation
122188-10 A0 Telect, Inc.
4-15
2. In the System Name field, type a name for the system (up to 16
characters) and press Enter. This name appears at the top of each
screen in the Craft interface.
3. Tab to the System Location field, type the location of the system
(up to 16 characters), and then press Enter.
4. Tab to the Contact Person field, type the name of the person users
should contact about the system (up to 16 characters), and then
press Enter.
5. Tab to the Date field and type the current date in the format
dd/mon/yy where “dd” is the day of the month, “mon” is the first 3
characters of the month name, and “yy” is the year (00-99). Press
Enter after typing in the date.
NOTE
The forward slash (/) must be used in entering the date. The colon (:) must
be used in entering the time.
6. Tab to the Time field and type the current time in military time for-
mat. Press Enter after typing in the time (hh:mm:ss).
7. Tab to the AIS Terminates LB field, specify whether receiving an
AIS signal will terminate any loopbacks that are set by pressing the
space bar to toggle between Yes and No, and then press Enter.
8. Tab to the Low Speed Type field, specify the low-speed type by
pressing the space bar to toggle between T1, E1 (lines 22-28 dis-
abled), E1 (every 4th line disabled), and Mixed, then press Enter.
9. Tab to the LS Remote LB Dir field, specify which direction to re-
ceive and transmit low-speed loopback loop-up and loop-down
codes by pressing the space bar to select between DS3 and DS1,
then press Enter.
10. Tab to the Active Card field, specify which M13 card by pressing
the spacebar to toggle between 1 and 2, then press Enter.
If you are switching active cards, a prompt appears asking you to
confirm the change.
a. Type y and press Enter. The current session is terminated.
b. Press Enter to start a new session. If you are using Telnet, you
must first reestablish the connection to the system.