4 Software Operation MIX 56 User Manual
4-34 Telect, Inc. 122188-10 A0
3. To clear the error counts for all 96 periods, tab to the [Clear] button
and press Enter. This also clears the High Speed 24-hour counts.
A prompt appears asking you to confirm the clear.
4. Type y and press Enter.
To View High-Speed Errors in 24-Hour Histories
The High Speed Errors-24 hr. screen updates every 15 minutes, displaying
DS3 error counts for two time periods: from Midnight the current day to
the end of the last completed 15-minute period and from Midnight the pre-
vious day to one second before Midnight the current day. When finished
viewing the error counts, you can clear both periods at once.
NOTE
During the first 15-minute period of the day (between 00:00:00 and
00:14:59) no error counts are shown in the 24-hour history screen. Howev-
er, you still can see error counts during this first 15-minute period by going
to the High Speed Errors-15 min. screen.
Step Action
1. From the Directory screen, type 12 to select High Speed Errors-24
hr. and press Enter. The High Speed Errors-24 hr. screen appears:
2. To clear both periods, tab to the [Clear] button and press Enter. This
also clears the High Speed 15-minute error counts.
MIX 56 by Telect MIX 56 Directory (Ctrl+D)
Help (?)
High Speed Errors-24 hr.
------------------------
[Clear]
CURRENT PREVIOUS
Span: 00:00:00-23:29:59 Span: 00:00:00-23:59:59
----------------------- -----------------------
ES: 00001 ES: 00001
SES: 00001 SES: 00001
CV: 00000 CV: 00000
LOSS: 00001 LOSS: 00000
AISS: 00002 AISS: 00000
FC: 00003 FC: 00000