Telect MIX 56 Network Card User Manual


 
MIX 56 User Manual 4 Software Operation
122188-10 A0 Telect, Inc.
4-51
When test mode “T1/E1 Test on High Speed Line” is selected then you also
specify:
1. Which channel of the muxed DS3 signal to insert the test pattern
on.
2. Whether to use a framed test signal or not.
3. What frame format to use if using a framed test signal.
4. What remote alarm format to use if T1 line and using a framed test
signal
When test mode “Unframed Test on Low Speed Line” is selected then you
also specify which low speed channel to do the test on.
To Specify a BER Test
Step Action
1. From the Directory screen, press 20 to select “BER Testing”, then
press enter. The “BER Testing” screen appears:
2. In the “Mode” field select the mode by pressing the spacebar to tog-
gle between “CBit DS3 Test on High Speed Line”, “Unframed Test
on Low Speed Line”, or “T1/E1 Test on High Speed Line” and then
pressing Enter.
MIX 56 by Telect MIX 56 Directory (CTRL+D)
Help (?)
BER Testing
-----------
Mode: T1/E1 Test on High Speed Line
Pattern: Disabled
Receiving Pattern: None
Low Speed Channel #: 1 Line Type: T1
Framed Signal: Yes
Frame Format: ESF
RAI: FS Bit
[Apply]