Vanguard Managed Solutions 7300 Series Network Router User Manual


 
Vanguard 7300 Installation 3-23
Connecting Vanguard 7300 DC Power
DC Power Supply
Connector Parts
Parts for the connector are not supplied by Vanguard Managed Solutions. This table
lists all required parts and pinouts for fabricating the connector:
DC Connector
Pinouts
This table lists the Vanguard 7310 DC Connector pinouts
:
Note
For detailed electrical specifications, refer to Appendix A, Specifications. For a
summary of cabling information, refer to Appendix B, Vanguard 7300 Cable
Connectors and Pinouts.
Quality Item AMP Part
Number
Description
1 Connector housing 206060-1 AMP CPC, 4-pin Socket (Female), Hood
3 Pins 66601-2 AMP gold-plated Type 111+ signal pins
1 Cable Clamp 206062-3 AMP Clamp, 2-screw, max. Cable Diam.: 8.36mm [.329 in.]
(Variable) Wire (18AWG min.) N/A UL/CSA-approved insulated stranded wire
Pin Number Description
1 -48V
2 -48V RTN
3 Chassis Ground
4 (No Connection)