Vanguard Managed Solutions 7300 Series Network Router User Manual


 
Vanguard 7300 Installation 3-25
Connecting Vanguard 7300 DC Power
Wiring a Vanguard
7330 DC Power
Supply
Use the procedures in this table for connecting DC power to the dual input terminal
blocks on a Vanguard 7330 Version 1 :
Note
Obtain UL/CSA-approved power cables and connectors with insulated crimp-on
terminals. Power cables must be rated for at least 8A input current. Use cable
harnesses and terminal-connector assemblies that conform to applicable
electrical codes.
Step Action
1 Be sure the Power On/Off switch on the front panel is in the Off position.
2 Connect the primary power input wires to the two terminals marked -48
and INPUT RTN on the left of the terminal blocks.
3 IMPORTANT: Connect the ground wire to the ground terminal with
the ground symbol at the right side of the terminal blocks.
4 Connect the power cables to the DC power sources.
5 Turn the Power On/Off switch on the front panel to the On position to
apply power to the Vanguard 7330.
6 Observe the DC OK LED at the rear of the power supply, under the
terminal blocks. LED status shows:
LED illuminated, the power supply is operating properly
LED not illuminated, power supply is not operating properly