Xerox 4500 ps eth Printer User Manual


 
AS/400 SCS-DCA Printing Using TCP/IP
Xerox 4500 PS ETH, Inst. & Operator's Guide
121
12. AS/400 SCS-DCA Printing Using TCP/IP
This chapter provides:
AS/400 definitions for SCS/DCA printing
Once these parameters have been configured, and the basic TCP/IP
installation of the Xerox 4500 PS ETH (equipped with an FSL top) has
been completed, direct SCS/DCA will be possible. This will off-load the
AS/400 as Host Print Transform is not used.
Requirements:
- AS/400 version 3.1 or higher with TCP/IP installed and a TCP/IP
configured Xerox 4500 PS ETH (equipped with an FSL top) with 5250
emulation
12.1 Create a remote output queue
The CRTOUTQ command is used to create a Remote output queue. This
will enable the AS/400 to automatically output SCS/DCA data directly to an
Xerox 4500 PS ETH (equipped with an FSL top).
The following example shows the values required to create queue called
PS23OUTQ.
Create Output Queue (CRTOUTQ)
Type choices, press Enter.
Output queue . . . . . . . . . . OUTQ > PS23OUTQ
Library . . . . . . . . . . . *CURLIB
Maximum spooled file size: MAXPAGES
Number of pages . . . . . . . *NONE
Starting time . . . . . . . .
Ending time . . . . . . . . .
+ for more values
Order of files on queue . . . . SEQ *FIFO
Remote system . . . . . . . . . RMTSYS > *INTNETADR
Remote printer queue . . . . . . RMTPRTQ > LPDPRT1SCS
Writers to autostart . . . . . . AUTOSTRWTR > 1
The value LPDPRT1SCS used for RMTPRTQ must match the SCS printer
queue defined in the Xerox 4500 PS ETH (equipped with an FSL top).
The default value is LPDPRT1SCS.