3Com 2200 Switch User Manual


 
8-8 CHAPTER 8: ADMINISTERING FDDI RESOURCES
To set tvxLowerBound:
1 From the top level of the Administration Console, enter:
fddi path tvxLowerBound
You are prompted for a station, path, and value. The Switch 2200 has one
station, which appears in brackets.
2 Press [Return].
3 Enter the path (
p = primary, s = secondary).
4 Enter the new minimum time value.
The default is 2500 microseconds (µs).
See the following example:
Select station [1]:
Select path(s) (p,s|all) [p]:
Station 1 Primary - Enter new value [2500]:
Setting
tmaxLowerBound
The tmaxLowerBound attribute specifies the minimum time value of
fddiMAC T-Max that will be used by any MAC that is configured onto this
path. This value specifies the boundary for how high T-Req (the requested
token rotation time) can be set.
To set tmaxLowerBound:
1 From the top level of the Administration Console, enter:
fddi path tmaxLowerBound
You are prompted for a station, path, and value. The Switch 2200 has one
station, which appears in brackets.
2 Press Return.
3 Enter the path (
p = primary, s = secondary).
4 Enter the new minimum time value.
The default is 165000 microseconds (µs).
See the example below:
Select station [1]:
Select path(s) (p,s|all) [p]:
s
Station 1 Primary - Enter new value [165000]:
Top-Level Menu
system
ethernet
fddi
bridge
ip
snmp
analyzer
script
logout
station
path
mac
port
display
tvxLowerBound
tmaxLowerBound
maxTreq
Top-Level Menu
system
ethernet
fddi
bridge
ip
snmp
analyzer
script
logout
station
path
mac
port
display
tvxLowerBound
tmaxLowerBound
maxTreq