Agilent Technologies N2610A Network Card User Manual


 
170 Agilent FrameScope 350 User’s Manual
7 System Operations
Network Settings
Network Settings
The Network Settings screen shows a summary of the network
configuration. This screen may also be accessed by pressing on
the FrameScope icon on the right of the Main Menu. This
includes the following:
The Network Settings screen can be reached by pressing on the
FrameScope Icon on the Network tab Main Menu or by pressing
System from the Network tab Main Menu and then pressing
Network Settings and then Edit.
The information displayed includes Host Name (FrameScope
350 name, which by default is FRSCOPE plus the last three hex
bytes of the MAC address, but it can be changed,) MAC address
of the FrameScope 350 (This is a factory setting that identifies
FrameScope uniquely among all Ethernet devices.), information
assigned by DHCP or manually, Network Connection (Auto or
Manual,) and whether Active Discovery and Measure Length are
enabled or disabled. To change any of the settings, press Edit
Settings.
IP Settings The first Network Settings Setup screen allows you
to select using DHCP to automatically configure the
FrameScope when connected to the network, or to manually
configure. If you manually configure, you are required to at least
enter a valid IP address and a valid subnet mask.
IP Address – This value uniquely identifies the
FrameScope in the TCP/IP network.
Subnet Mask – This value is combined with the IP Address
to define the subnet to which the FrameScope belongs.