User’s Guide
3-30 Forms Handling
The DPCL sequence to change profiles is active in all emulations.
Select Profile (form) <n> ESC$$E1.I18;<n>.X.
CODE FORMAT
ASCII: ESC $ $ E 1 . I 1 8 ; <n> . X .
DECIMAL: 27 36 36 69 49 46 73 49 56 59 n 46 88 46
HEXADECIMAL: 1B 24 24 45 31 2E 49 31 38 3B n 2E 58 2E
Description: This command is used to select Profile n where values of n range from 1 to 4.
The Paper Path may be selected by the Host Computer by configuring the
‘Path’ feature to Main, Alt, or Either, and by selecting the Profile using this
sequence.
Example: 10 rem select Profile 2
20 print chr$(27);”$$E1.I18;2.X.”
Comment: See Chapter 4 for a description of Profile features including the ‘Path’
feature.
* Only the Main selection is available on single path units.