AMX NXT-1200V Computer Monitor User Manual


 
Programming
142
1200V Modero Video Touch Panels
"^" Button Commands (Cont.)
^BOR
Set a border to a
specific border
style associated
with a border
value for those
buttons with a
defined address
range.
Refer to theTPD4 Border Styles by Name table on page 130 for more
information.
Syntax:
"'^BOR-<vt addr range>,<border style name or border value>'"
Variable:
variable text address range = 1 - 4000.
border style name = Refer to theTPD4 Border Styles by Name table on page 130.
border value = 0 - 41.
Examples:
SEND_COMMAND Panel,"'^BOR-500.504&510.515,10'"
Sets the border by number (#10) to those buttons with the variable text range of 500-504
& 510-515.
SEND_COMMAND Panel,"'^BOR-500.504&510,AMX Elite -M'"
Sets the border by name (AMX Elite) to those buttons with the variable text range of
500-504 & 510-515.
The border style is available through the TPDesign4 border-style drop-down list. Refer to
theTPD4 Border Styles by Name table on page 130 for more information.
^BOS
Set the video
window slot ID #
to the new Slot
ID #.
The new Slot ID # is set only if the specified slot is not the same as the current slot
selected. Passthru sets the passthru mode to On.
This is an optional parameter and ONLY passes data to the PC.
Syntax:
"'^BOS-<vt addr range>,<button states range>,<slot
number>,<passthru>'"
Variable:
variable text address range = 1 - 4000.
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons
1 = Off state and 2 = On state).
slot number = 0 = No Video Fill (Video Off)
1 = Composite Video (Video Fill) (Video On)
2 = Component RGB
3 = Streaming Video. 1200V panels only have Slot 1 available.
passthru = Passthru disable = 0 or Passthru enable = 2.
Example:
SEND_COMMAND Panel,"'^BOS-500,1,1'"
Sets the button to display Composite video with no pass-thru.
Refer to theVideo Adjustment Slide-Out Option Bar section on page 101 for more informa-
tion on the slot assignments within a panel.
^BPP
Set or clear the
protected page flip
flag of a
button.
Zero clears the flag.
Syntax:
"'^BPP-<vt addr range>,<protected page flip flag value>'"
Variable:
variable text address range = 1 - 4000.
protected page flip flag value range = 0 - 4 (0 clears the flag).
Example:
SEND_COMMAND Panel,"'^BPP-500,1'"
Sets the button to protected page flip flag 1 (sets it to password 1).