Avaya 8400B Plus Barcode Reader User Manual


 
AT Command Set
A-26 Issue 2 November 1996
Command: &T
Function: Control diagnostic and test facilities.
Type: immediate
Arguments: The &T command accepts one of eight arguments (see
comment 2) as follows:
0 (or no option) terminate any test in progress (see
comment 3).
1 initiate local loopback test.
2 same as 1.
3 initiate local data loopback test.
4 allow remote loopback requests from the remote
system (factory-default selection).
5 deny remote loopback requests from the remote
system.
6 initiate remote loopback test.
7 initiate remote loopback test with self-test.
8 initiate local loopback test with self-test.
S-Register: Bits 0 and 26 of S16 are set according to the
argument used with the &T command.
Example: AT&T3
(see comment 1)
Table A-1. Accepted AT Command Labels Continued
Label Description
ENTER