S-Registers
C-18 Issue 2 November 1996
Register: S11
Description: This S-register determines the duration and spacing of
tones in Dual-Tone Multifrequency (DTMF) dialing.
Range of Values: Value may be 000 through 255 milliseconds;
factory-default value is 95 milliseconds.
Storable: no
Comments: This feature is unnecessary in the DCP operating
environment of the 8400B Plus Data Module. The value
in S11 may be set or read but is always ignored.
See Also: none
Table C-1. Labels Used in S-Registers — Continued
Label Description