Black Box MD1640A Modem User Manual


 
106
SERIES II INTELLIGENT DATA/FAX MODEMS
Table 7-1. Modem LOGIN, Setup and Remote Escape Code
Procedures
To change your modem’s LOGIN Password and Setup Password:
Step
Procedure
Note: Passwords are upper/lower case sensitive. The case you enter
here is the case that must be used at Log-In.
1. Type AT#IBLACK BOX and hit RETURN. Your modem will
respond with:
OK (if the LOGIN Password is wrong, the modem’s response is
ERROR)
2. Type AT#SMODEMSETUP and hit RETURN. Your modem will re-
spond with the following:
OK (or ERROR if wrong Setup Password)
Note: At this point you can change the LOGIN Password and
Setup Password.
3. Type AT#I=xxxxxxxxxx (with any keyboard characters used,
minimum 6 maximum 10) and hit RETURN. Your modem
responds with:
OK
4. Type AT#S=yyyyyyyyyy (with keyboard characters used,
minimum 6 maximum 10) and hit RETURN. Your modem
responds with:
OK
To change your Remote Configuration feature status:
5. If you want Remote Configuration off, set S-Register S13 to 0
(zero). Refer to Chapter 6 for details on how to set S-Register
values.
6. If you want Remote Configuration on and wish to change the
Remote Escape Character, change the S-Register S13 value. If you
leave it at the default value, decimal 37 (% sign) will be your
modem’s remote escape character.