Black Box MD1640A Modem User Manual


 
153
APPENDIX C: Command Summary
%DFn n = 0 or 1 *%DF0 Line Probe Data in Graph Format.
%DF1 Line Probe Data in Table Format.
%DPn n = 0 or 1 *%DP0 do not read Line Probe
Information from DSP during handshaking.
%DP1 read Line Probe Information from
DSP during handshaking.
$Dn n = 0 or 1 *$D0 disables DTR Dialing.
$D1 enables DTR Dialing.
En n = 0 or 1 E0 means do not echo Command Mode
Character.
*E1 means do echo Command Mode
characters.
* Factory Default Setting
Command
Values
Description
&En n = 0 thru 15 &E0 means no error correction.
*&E1 means V.42 Auto-reliable Mode.
&E2 means V.42 Reliable Mode.
&E3 means no modem-initiated flow
control.
*&E4 means CTS modem-initiated flow
control.
&E5 means Xon/Xoff modem-initiated flow
control.
*&E6 means Xon/Xoff not passed through.
&E7 means Xon/Xoff passed through.
*&E8 means Enq/Ack pacing off.
&E9 means Enq/Ack pacing on.
*&E10 means Normal Mode flow control
off.
&E11 means Normal Mode flow control on.
&E12 means Pacing off.
*&E13 means Pacing on.
&E14 means data compression disabled.
*&E15 means data compression enabled.