Black Box MD1640A Modem User Manual


 
162
SERIES II INTELLIGENT DATA/FAX MODEMS
location. The (-) preceding the phone number
enables direct entry when the caller uses the
correct password without the callback modem
having to return the call. The ??? entry at the end
of the phone number represents an extension
added to the main phone number. The Nxx is the
memory location of the callback phone number
and password.
#Pn Parity of the prompt messages sent by the callback
modem.
#P0 is no parity
#P1 is odd parity
#P2 is even parity
Command
Description
#RCBNxx Erases the callback password stored at memory
location xx. Memory locations are 0 to 29.
#RDNxx Erases the callback phone number stored at
memory location xx. Memory locations are 0 to 29.
Password Command Summary
Command Description
#Ixxxxxxxxxx Login Password is any keyboard characters (x)
(upper/lower case sensitive), minimum 6 and
maximum 10 characters. The default Login
Password is #IBLACK BOX.
#Syyyyyyyyyy Setup Password is any keyboard characters (y)
(upper/lower case sensitive), minimum 6 and
maximum 10 characters. The default Setup
Password is #SMODEMSETUP.