SERIES II INTELLIGENT DATA/FAX MODEMS
If the $VD1 command is entered when in Auto-Answer mode, the
modem answers immediately upon receiving the first ring.
There is no disconnect message (NO CARRIER) if a normal connection
is made.
V.25bis Set-Up and Initialization
Before you operate your modem in the V.25bis mode, you need to make
sure it is set up properly (various RS-232 lines such as DSR and CTS act
as specified in the V.25bis standard). Setup involves proper DIP-Switch
settings and soft-switches (software controlled conditions).
V
.25bis DIP-Switches
#1 Unforced DTR
#2 NA
#3 NA
#4 NA
#5 Auto-Answer enabled
#6 Async - Max throughput set
Sync - Slave Clocking unforced
#8 - Command Mode forced
#9 - Digital Loopback Off
#10 - Dial-Up
#11 - Async - AT/Series II Resp.
#12 - Async/Sync mode set per requirements