Cisco Systems SCE 1000 2xGBE Network Router User Manual


 
Chapter 4 Installation and Maintenance
Removing and Replacing a Power Supply Unit
Cisco SCE 1000 2xGBE Installation and Configuration Guide
OL-7821-05 4-19
Warning
Wiring should be done by a professional in accordance with state and local electrical codes.
To reconnect the DC-input power to the SCE 1000 platform, complete the following steps:
Step 1 Ensure that the DC power line input leads are disconnected from the power source.
Step 2 Using the number 2 Phillips screwdriver, remove the protective plate from the terminal block.
Step 3 Insert one receptacle screw into the hex or loop connector on one power line input, insert the
screw with the connector into the corresponding lead receptacle and tighten the receptacle screw
using the number 2 Phillips . Repeat for the remaining power line input lead.
Figure
4-15: Connecting the DC Power
Note
The color coding of the DC-input power supply leads depends on the color coding of the DC power
source at your site. Make certain the lead color coding you choose for the DC-input power supply
matches lead color coding used at the DC power source.
Note
Use 12 AWG (2.5 mm) copper wire only with hex or loop connectors. Ring terminals must be UL
approved and suitable for 12 AWG wire.
Step 4 Using the number 2 Phillips screwdriver, securely fasten the protective plate to the terminal block.
Step 5 Connect the DC power line input leads to the DC power source through a fast 10A circuit breaker.
Step 6 Turn the on/off switch to the on () position.
Step 7 Look at the IN and OK LEDs on the power supply unit and the corresponding Power LED on the
front panel. If the new DC-input power supply unit is operating properly, these LEDs will be
glowing green.