Chapter 5 Connecting the Management Interfaces and Performing Initial System Configuration
Initial System Configuration
Cisco SCE 1000 2xGBE Installation and Configuration Guide
OL-7821-05 5-21
EXAMPLE 3:
Following is a sample topology configuration for a redundant inline topology.
Connection mode — Inline
For a redundant topology, link bypass on-failure should be Cutoff, so that operation switches
to the backup link.
After operation of the system resumes, and the SCE 1000 reboots, the SCE 1000 will resume
operation. (Admin status after abnormal reboot is Operational.)
Would you like to enter the Topology configuration menu? [no]: y
Enter Connection mode:
1- inline
2- receive-only
Enter your choice [1]: 2
Enter On-failure behavior:
1- Bypass
2- Cutoff
Enter your choice [1]:2
Enter admin status of the SCE after abnormal boot:
1- Operational
2- Not-Operational
Enter your choice [1]:
Data collection for the system configuration is completed.
Step 10: Completing and Saving the Configuration
When you have completed the entire configuration, the system checks for errors. If errors are
found, a warning message appears. When the configuration is error-free, you may apply and save
it.
To complete and save the configuration, complete the following steps:
Step 1 The system informs you that data collection is complete.
We recommend that you view the entire new configuration before it is applied.
Type y and press Enter.
Note that there is no default.
If there are no errors, go to step 3.
Data collection for the system configuration is completed.
Would you like to view the new configuration before it is applied?
[yes/no]: y
Step 2 If any errors are detected, you may choose to view them.
Press Enter.
Found errors in the new configuration, would you like to view them? [yes]:
The following errors were found:
Warning - RDR formatter destination 10.1.1.1 is not allowed in the IP
access-class.
Step 3 You are asked whether to apply and save the configuration.