The previous example shows four Fibre Channel devices on this SCSI bus.
The Fibre Channel adapter in question, emx0, at SCSI ID 7, is denoted by
the presence of the emx0 designation.
Use the emxmgr -t command to display the Fibre Channel topology for
the adapter. For example:
# emxmgr -t emx1
emx1 state information:
1
Link : connection is UP
Point to Point
Fabric attached
FC DID 0x210413
Link is SCSI bus 3 (e.g. scsi3)
SCSI target id 7
portname is 1000-0000-C921-07C4
nodename is 1000-0000-C921-07C4
N_Port at FC DID 0x210013 - SCSI tgt id 5 :
2
portname 5000-1FE1-0001-8932
nodename 5000-1FE1-0001-8930
Present, Logged in, FCP Target, FCP Logged in,
N_Port at FC DID 0x210113 - SCSI tgt id 1 :
2
portname 5000-1FE1-0001-8931
nodename 5000-1FE1-0001-8930
Present, Logged in, FCP Target, FCP Logged in,
N_Port at FC DID 0x210213 - SCSI tgt id 2 :
2
portname 5000-1FE1-0001-8941
nodename 5000-1FE1-0001-8940
Present, Logged in, FCP Target, FCP Logged in,
N_Port at FC DID 0x210313 - SCSI tgt id 4 :
2
portname 5000-1FE1-0001-8942
nodename 5000-1FE1-0001-8940
Present, Logged in, FCP Target, FCP Logged in,
N_Port at FC DID 0x210513 - SCSI tgt id 6 :
2
portname 1000-0000-C921-07F4
nodename 2000-0000-C921-07F4
Present, Logged in, FCP Initiator, FCP Target, FCP Logged in,
N_Port at FC DID 0xfffffc - SCSI tgt id -1 :
3
portname 20FC-0060-6900-5A1B
nodename 1000-0060-6900-5A1B
Present, Logged in, Directory Server,
N_Port at FC DID 0xfffffe - SCSI tgt id -1 :
3
portname 2004-0060-6900-5A1B
nodename 1000-0060-6900-5A1B
Present, Logged in, F_PORT,
1 Status of the emx1 link. The connection is a point-to-point fabric
(switch) connection, and the link is up. The adapter is on SCSI bus 3
at SCSI ID 7. Both the port name and node name of the adapter (the
660 Using Fibre Channel Storage