Compaq AA-RHGWB-TE Computer Hardware User Manual


 
Table 103: Installing a KZPSA-BB or KZPBA-CB for use with External
Termination (cont.)
Step
Action Refer to:
7
Use the show pk* or show isp* console
commands to determine the status of the
KZPSA-BB or KZPBA-CB console environment
variables, and then use the set console
command to set the KZPSA-BB bus speed to
fast, termination power to on, and the KZPSA
or KZPBA-CB SCSI bus ID.
Section 10.1.4.1 through
Section 10.1.4.3 and
Example 106 through
Example 109
_____________________ Notes _____________________
Ensure that the SCSI ID that you use is distinct from all other SCSI IDs
on the same shared SCSI bus. If you do not remember the other SCSI
IDs, or do not have them recorded, you must determine these SCSI IDs.
You will have problems if you have two or more SCSI adapters at the
same SCSI ID on any one SCSI bus.
8
Repeat steps 1 through 7 for any other KZPSA-BBs
or KZPBA-CBs to be installed on this shared
SCSI bus on other member systems.
9
Install the remaining SCSI bus hardware needed
for storage (DWZZA(B), RAID array controllers,
storage shelves, cables, and terminators).
Section 9.4
BA350 storage shelf. Section 9.3.1,
Section 9.4.1.1, and
Section 9.4.2.1
Non-UltraSCSI BA356 storage shelf. Section 9.3.2.1,
Section 9.4.1.2, and
Section 9.4.2.2
Ultra BA356 storage shelf. Section 9.3.2.2,
Section 9.4.1.3, and
Section 9.4.2.3
HSZ40 or HSZ50 RAID array controller Section 9.4.3
10
Install the tape device hardware and cables
on the shared SCSI bus as follows:
Chapter 8
TZ88 Section 8.1
TZ89 Section 8.2
Compaq 20/40 GB DLT Tape Drive Section 8.3
TZ885 Section 8.4
TZ887 Section 8.5
TL891/TL892 MiniLibrary Section 8.6
108 Configuring Systems for External Termination or Radial Connections
to Non-UltraSCSI Devices