144 Using the Storage Management Service
omreport Virtual Disk Status
omconfig Global Commands
The following sections provide the omconfig command syntax required to execute the global commands.
When executed, these commands apply to all controllers. These global commands also correspond to the
global tasks provided by the Storage tree view object’s Information/Configuration subtab.
omconfig Global Enable Smart Thermal Shutdown
By default, the operating system and server shut down when the PV220S and PV221S enclosures reach a
critical temperature of 0 or 50
° Celsius. If you have implemented connector redundancy on the PV220S
and PV221S enclosures, however, you can specify that only the enclosure and not the operating system
and server be shut down when the enclosure reaches a critical temperature of 0 or 50
° Celsius. Specifying
that only the enclosure be shutdown during excessive temperatures is known as Smart Thermal
Shutdown. See the online help for more information.
Use the following omconfig command syntax to enable smart thermal shutdown.
Complete Syntax
omconfig storage globalinfo action=enablests
Table 8-14. omreport Virtual Disk Commands
Required Command Levels (1, 2, 3) Optional name=value pairs Use
omreport storage vdisk Displays property information for
all virtual disks on all controllers.
controller=id
where id is the controller number.
For example: controller=0.
Displays all virtual disks on the
specified controller.
controller=id vdisk=id
where id is the controller number
and the virtual disk number. For
example: controller=0 vdisk=1.
Displays the specified virtual disk
on the controller.
Table 8-15. omconfig Global Commands
Required Command Levels (1, 2, 3) Optional name=value pairs
omconfig storage globalinfo
action=enablests
action=disablests
action=globalrescan