Dell Command Line Interface Network Card User Manual


 
omreport: Viewing System Status Using the Instrumentation Service 37
A 2-way set-associative cache directly maps two specific lines of memory to the same two lines of cache.
A 1-way set-associative cache directly maps a specific line of memory in the same line of cache.
For example, line 0 of any page in memory must be stored in line 0 of cache memory.
Cache Device Supported Type is the type of static random access memory (SRAM) that the device
can support.
Cache Device Current Type is the type of the currently installed SRAM that the cache is supporting.
External Socket Name Silk Screen Name is the name printed on the system board next to the socket.
Error Correction Type identifies the type of error checking and correction (ECC) that this memory can
perform. Examples are correctable ECC or uncorrectable ECC.
This report shows cache information for each cache present on the microprocessor.
omreport chassis pwrsupplies
Use the omreport chassis pwrsupplies command to view properties of your system’s power supplies.
Ty p e :
omreport chassis pwrsupplies index=
n
The index parameter is optional. If you do not specify the index, Server Administrator displays
properties for all power supplies in your system. If you specify the index, Server Administrator displays
properties for a specific processor.
For each power supply in the system, values display for the following fields: Status, Location, Ty p e ,
Max Wattage, and Online Status.
omreport chassis remoteaccess
NOTE: This command is applicable to Dell
PowerEdge
x8xx and x9xx systems only.
Use the omreport chassis remoteaccess command to view general information on baseboard
management controller (BMC) and remote access control (RAC) if DRAC is installed.
Ty p e :
omreport chassis remoteaccess
The output from the omreport chassis remoteaccess command lists each of the valid parameters.
Table 3-5 shows the available settings.