Dell Command Line Interface Network Card User Manual


 
178 Using the Storage Management Service
omconfig Delay Battery Learn Cycle
Use the following omconfig command to delay the battery learn cycle for a specified period of time.
The battery learn cycle can be delayed for a maximum of seven days or 168 hours.
Complete Syntax
omconfig storage battery action=delaylearn controller=id battery=id
days=d hours=h
where id is the controller ID and battery ID as reported by the omreport command. To obtain this value,
enter omreport storage controller to display the controller IDs and then enter omreport storage battery
controller=ID to display the ID for the controller battery.
Example Syntax
For example, to delay the learn cycle for three days and 12 hours on controller 1, enter:
omconfig storage battery action=delaylearn controller=1 battery=0
days=3 hours=12
omconfig Connector Commands
The following sections provide the omconfig command syntax required to execute connector tasks.
omconfig Rescan Connector
Use the following omconfig command to rescan a controller connector. This command rescans all
connectors on the controller and is therefore similar to performing a controller rescan.
NOTE: This command is not supported on SAS controllers.
Complete Syntax
omconfig storage connector action=rescan controller=id connector=id
where id is the controller ID and the connector ID as reported by the omreport command. To obtain
these values, enter omreport storage controller to display the controller IDs and then enter omreport
storage connector controller=ID to display the IDs for the connectors attached to the controller.
Table 8-25. omconfig Connector Commands
Required Command Levels (1, 2, 3) Optional name=value pairs
omconfig storage connector
action=rescan controller=id connector=id