Dell Command Line Interface Network Card User Manual


 
omconfig: Managing Components Using the Instrumentation Service 93
omconfig system platformevents
Use the omconfig system platformevents command to configure shutdown action, if any, to be taken for a
specific platform event. You can also enable or disable platform event filter alert generation.
NOTICE: If you set a platform event shutdown action to anything other than "none", your system will forcefully
shutdown when the specified event occurs. This shutdown is initiated by firmware and is carried out without first
shutting down the operating system or any of the applications running on your system.
Table 4-23 shows the valid parameters for the command.
NOTE: Alert settings are mutually exclusive and can be set one at a time only. The action settings are also mutually
exclusive and can be set one at a time only. However, alert and action settings are not mutually exclusive of
each other.
Table 4-24 lists the components and the events for which you can set platform events. Components are
listed in alphabetical order, except that warning events always precede failure events for a component.
Table 4-23. Shutdown Action
Shutdown Action Description
alert=disable Disables the SNMP alert.
alert=enable Enables the SNMP alert to be sent.
action=none Takes no action when the system is hung or has crashed.
action=powercycle Turns the electrical power to the system off, pauses, turns the power on, and
reboots the system.
action=poweroff Turns off the electrical power to the system.
action=reboot Forces the operating system to shut down and initiates system startup,
performs BIOS checks, and reloads the operating system.
Table 4-24. omconfig system platformevents
Event Name Description
alertsenable=true | false true: Enables generation of platform event filter alerts.
false: Disables generation of platform event filter alerts.
NOTE: This setting is independent of the individual platform event filter alert settings.
For a platform event filter to generate an alert, both the individual alert and the global
event alert must be enabled.
event=batterywarn Sets action or enables/disables alert generation when a battery device detects that
the battery is pending a failure condition.
event=batteryfail Sets action or enables/disables alert generation when a battery device detects that
the battery has failed.
event=discretevolt Sets action or enables/disables alert generation when a discrete voltage probe
detects that the voltage is too low for proper operation.