Dell Command Line Interface Network Card User Manual


 
80 omconfig: Managing Components Using the Instrumentation Service
config=serialoverlan enable=true | false true: Enables serial over LAN for the BMC.
false: Disables serial over LAN for the BMC.
baudrate=9600 | 19200 | 38400 | 57600
| 115200
9600: Sets the volatile and nonvolatile
connection speed to 9600 bits per second.
19200: Sets the volatile and nonvolatile
connection speed to 19200 bits per second.
38400: Sets the volatile and nonvolatile
connection speed to 38400 bits per second.
57600: Sets the volatile and nonvolatile
connection speed to 57600 bits per second.
115200: Sets the volatile and nonvolatile
connection speed to 115200 bits per second.
NOTE: Baud rates of 9600 and 19200 are
supported on PowerEdge 1800, 1850, 2800, and
2850 systems.
Baud rates of 9600, 19200, and 57600 are
supported on PowerEdge x9xx systems.
Baud rate of 115200 is supported on certain
systems that have a DRAC 5 installed.
privilegelevel=administrator | operator
| user
administrator: Sets the maximum privilege
level that can be accepted on a serial over
LAN channel, to Administrator.
operator: Sets the maximum privilege level
that can be accepted on a serial over LAN
channel, to Operator.
user: Sets the maximum privilege level that
can be accepted on a serial over LAN channel,
to User.
config=settodefault Takes the default configuration settings.
config=terminalmode deletecontrol=outputdel |
outputbkspspbksp
outputdel: BMC outputs a <del> character
when <bksp> or <del> is received.
outputbkspspbksp: BMC outputs a
<bksp><sp><bksp> character when
<bksp> or <del> is received.
Table 4-12. omconfig chassis remoteaccess (continued)
name=value pair 1
config=
name=value pair 2 Description