Dell Command Line Interface Network Card User Manual


 
26 omreport: Viewing System Status Using the Instrumentation Service
omreport chassis Commands
Use omreport chassis commands to view details for the entire chassis or for a particular component.
omreport chassis
When you type:
omreport chassis
Server Administrator displays a general status for your main system chassis components.
NOTE: When you issue CLI commands to a server module in a modular system, chassis refers only to the server module.
NOTE: As with all output shown in this guide, the following output is an example and may vary depending on your
system configuration.
omreport chassis acswitch
Use the omreport chassis acswitch command if your system has redundant AC power lines that are
configured in a failover arrangement. When you type:
omreport chassis acswitch
Server Administrator displays the following output:
SEVERITY : COMPONENT
Ok : Fans
Critical : Intrusion
Ok : Memory
Ok : Power Supplies
Ok : Temperatures
Ok : Voltages
AC Failover Switch
AC Switch Redundancy
Redundancy Status : Full
Number of devices required for full
redundancy
:2
Redundancy Mode :
Redundancy Configuration : Input Source Line 1, upon
redundancy restoration, return
to Line 1