omreport: Viewing System Status Using the Instrumentation Service 33
omreport chassis leds
Use the omreport chassis leds command to find out whether clear hard drive fault is supported and what
severity level lights up the LED. Type:
omreport chassis leds index=
n
The index parameter is optional. If you do not specify the index, Server Administrator displays a
summary of LED information for chassis 0. If you specify the index, Server Administrator displays a
summary for a specific chassis.
The following is an example output:
omreport chassis memory
Use omreport chassis memory to see details for each memory module slot in your system. If your system
supports redundant memory, this command also displays the status, state, and type of memory
redundancy implemented on your system. Type:
omreport chassis memory index=
n
The index parameter is optional. If you do not specify the index, Server Administrator displays
information for all memory on your system. If you specify the index, Server Administrator displays a
summary for a specific memory module.
Output for an occupied memory slot may resemble the following:
An unoccupied memory slot still has a connector name. Output for an unoccupied memory slot may
resemble the following:
Flash chassis indentify LED state
Flash chassis indentify LED
timeout value
: Off
: 300
Index
Status
Connector Name
Type
Size
: 1
: OK
: DIMM_B
: SDRAM-SYNCHRONOUS
: 256 MB
Index
Status
Connector Name
Type
Size
: 2
: Unknown
: DIMM_D
: Not Occupied
: Unknown