Dell Command Line Interface Network Card User Manual


 
Using the Storage Management Service 177
omconfig Battery Commands
The following sections provide the omconfig command syntax required to execute battery tasks.
omconfig Recondition Battery
Use the following omconfig command to recondition a controller battery. For more information on
batteries and the recondition process, see the online help.
Complete Syntax
omconfig storage battery action=recondition controller=id battery=id
where id is the controller ID and battery ID as reported by the omreport command. To obtain this value,
enter omreport storage controller to display the controller IDs and then enter omreport storage battery
controller=ID to display the ID for the controller battery.
Example Syntax
For example, to recondition the battery on controller 1, enter:
omconfig storage battery action=recondition controller=1 battery=0
omconfig Start Battery Learn Cycle
Use the following omconfig command to start the battery learn cycle.
Complete Syntax
omconfig storage battery action=startlearn controller=id battery=id
where id is the controller ID and battery ID as reported by the omreport command. To obtain this value,
enter omreport storage controller to display the controller IDs and then enter omreport storage battery
controller=ID to display the ID for the controller battery.
Example Syntax
For example, to start the learn cycle on controller 1, enter:
omconfig storage battery action=startlearn controller=1 battery=0
Table 8-24. omconfig Battery Commands
Required Command Levels (1, 2, 3) Optional name=value pairs
omconfig storage battery
action=recondition controller=id battery=id
action=startlearn controller=id battery=id
action=delaylearn controller=id battery=id
days=d hours=h