Dell Command Line Interface Network Card User Manual


 
76 omconfig: Managing Components Using the Instrumentation Service
The output from the omconfig chassis remoteaccess command lists each of the available configurations.
Table 4-3 shows the valid parameters:
Table 4-12. omconfig chassis remoteaccess
name=value pair 1
config=
name=value pair 2 Description
config=advsol characcuminterval=number number: Sets the character accumulate
interval in 5 millisecond intervals.
charsendthreshold=number number: Sets the number of characters. BMC
automatically sends a serial over LAN data
packet that contains this number of
characters as soon as this number of
characters (or greater) has been accepted
from the baseboard serial controller into
the BMC.
config=nic enable=true | false true: Enables IPMI over LAN.
false: Disables IPMI over LAN.
encryptkey=text
confirmencryptkey=text
text: Text used for encryption and
confirmation of encryption.
NOTE: The option text is supported only on
PowerEdge x9xx systems.
gateway=Gateway Gateway: Sets a gateway address if you have
selected static as the IP address source for the
BMC LAN interface.
enablenic=true | false true: Enables DRAC NIC.
false: Disables DRAC NIC
NOTE: The option enablenic is supported on
PowerEdge x9xx systems that have DRAC 5
installed.
IP address=IP ip: Sets the IP address if you have selected
static as the IP address source for the BMC
LAN interface.