Delta Electronics ASDA-B Series Network Card User Manual


 
Revision January, 2009 7-1
Chapter 7 Servo Parameters
7.1 Definition
There are following five groups for drive parameters:
Group 0: Monitor parameter (example: P0-xx)
Group 1: Basic parameter (example: P1-xx)
Group 2: Extension parameter (example: P2-xx)
Group 3: Communication parameter (example: P3-xx)
Group 4: Diagnosis parameter (example: P4-xx)
There is following one group for keypad parameters:
Group 8: Keypad parameter (example: P8-xx)
Abbreviation of control modes:
P : Position control mode
S : Speed control mode
T : Torque control mode
Explanation of symbols (marked after parameter)
() Read-only register, such as P0-00, P0-01, P4-00.
() Parameter cannot be set when Servo On (when the servo drive is enabled).
() Parameter is effective only after the servo drive is restarted (after switching power off and on), such
as P1-01.
() Parameter setting values are not retained when power is off.