Delta Electronics ASDA-B Series Network Card User Manual


 
Chapter 7 Servo Parameters|ASDA-B Series
7-12 Revision January, 2009
Position Control
Control
Mode
Parameter Name Function Default Unit
P S T
P1-01
CTL Control Mode and Output Direction 0
pulse
rpm
N.M
{ { {
P1-02
PSTL Speed and Torque Limit 0 N/A
{ { {
P1-55 MSPD Maximum Speed Limit rated speed rpm
{ { {
P1-12
~ P1-14
TQ1 ~ 3 1st ~ 3rd Torque Limit 100 %
{ { {
P1-46
GR3 Encoder Output Pulse Number 2500 pulse
{ { {
External pulse control command (P mode)
P1-00
PTT External Pulse Input Type 2 ---
{
P1-41
TCM Max. Analog Torque Limit 100 %
{ {
P1-44
GR1
Electronic Gear Ratio (1st Numerator)
(N1)
1
pulse
{
P1-45
GR2 Electronic Gear Ratio (Denominator) 1
pulse
{
P1-15
GR4
Electronic Gear Ratio (2nd Numerator)
(N2)
1
pulse
{
Explanation of symbols (marked after parameter)
() Read-only register.
() Parameter cannot be set when Servo On (when the servo drive is enabled).
() Parameter is effective only after the servo drive is restarted (after switching power off and on).
() Parameter setting values are not retained when power is off.