C2-1: Pulse input (Open collector – internal power)
7
VDD
19 /SIGN
20 SIGN
COM-
22 PULSE
13
21 /PULSE
DC24V
Max. input pulse
frequency is 200kpps
S
ervo Drive
Approx.
1K
Approx.
1K
50
50
50
50
C2-2: Pulse input (Open collector – external power)
7
VDD
19 /SIGN
20 SIGN
COM-
22 PULSE
13
21 /PULSE
Vdc
DC24V
Max. input pulse
frequency is 200kpps
S
ervo Drive
Approx.
1K
Approx.
1K
50
50
50
50