Digi 90000566_H Network Router User Manual


 
set serial
190 Chapter 2 Command Descriptions
baudrate=bps
The baud rate in bits per second. The default is 9600.
csize={5|6|7|8}
The character size, which can be 5, 6, 7, or 8 bits. The default is 8.
flowcontrol={hardware|software|none}
Specifies which kind of flow control is used on the line.
hardware
Hardware flow control (RTS/CTS).
software
Software flow control (Xon/Xoff).
none
No flow control.
The default is “software.”
parity={none|even|odd|mark|space}
The parity used for the line.
none
No parity.
even
Even parity.
odd
Odd parity.
mark
Mark parity.
space
Space parity.
The default is “none.”
stopb={1|2}
The number of stop bits per character to use on this line. The value used
here must match the setting on the device connected to this port. Use 1
or 2 stop bits.
The default is 1 stop bit.
Example #> set serial baudrate=9600 flowcontrol=hardware
See also "revert" on page 61.
"show" on page 249.