Digi 90000566_H Network Router User Manual


 
set alarm
Chapter 2 Command Descriptions 71
Configure alarms based on GPIO pin states, where n is the GPO pin number
set alarm range={1-32} mode=gpio
[pins=list of pins|highpins=list_of highpins|
lowpins=list of lowpins|pin{n}={high|low|ignore}|
trigger_interval=seconds|reminder={on|off}|
reminder_interval=seconds]
Configure alarms based on data pattern matching
set alarm mode=match
match=string
Configure alarms based on mobile signal strength (GSM)
set alarm mode=rssi_gsm
sig_strength_threshold=threshold
time=time
optimal_alarms_enabled={yes|no}
Configure alarms based on signal strength (CDMA)
set alarm mode={rssi_1xrtt|rssi_1xevdo|ecio_1xrtt|ecio_1xevdo}
sig_strength_threshold=threshold
time=time
optimal_alarms_enabled={yes|no}
Configure alarms based on mobile temperature
set alarm mode=mobile_temp
temperature=temperature
optimal_alarms_enabled={yes|no}
Configure alarms based on mobile service unavailable
set alarm mode={1xevdo_unavail|mobile_unavail}
time=time
optimal_alarms_enabled={yes|no}
Configure alarms based on mobile configuration changes
set alarm mode=config_change
Set alarms based on cellular data traffic
set alarm mode=cell_data
cell_data=byte count threshold
cell_data_type={receive|transmit|total}
time=max time
Display current alarm settings
set alarm [range={1-32}]