Digi 90000566_H Network Router User Manual


 
set alarm
72 Chapter 2 Command Descriptions
Options General alarm options
state= {on|off}
Enables or disables all alarms.
on
Enables all alarms.
off
Disables all alarms. To avoid false errors, it is recommended that you
configure alarms while alarms are disabled, and enable alarms after
they are fully configured.
The default is “off.”
mailserverip=ipaddress
Used to configure IP address of the mail server to which alarm-triggered
emails are sent.
from=string
The text to be included in the “from” field of an alarm-triggered email.
cwm={on|off}
Enables or disables sending of alarm notifications to the Connectware
Manager server.
on
Send all alarm notifications to the Connectware Manager server. Turn
this option on if your Digi Connect device is managed by Connectware
Manager. Enabling this option is useful because it allows all alarms to
be monitored from one location, the Connectware Manager. Enabling
this option also allows Digi Connect devices to send alarms to clients
that would otherwise be unreachable from the Digi Connect device,
either because the Digi Connect device is behind a firewall or not on
the same network as the alarm destination.
off
Disables sending of alarm notifications to the Connectware Manager
server. Leave this option off if you do not manage your devices with
Connectware Manager or if you wish to have alarms sent from the
device, for example, because an SNMP trap destination is local to the
device, not the Connectware Manager server.
For more information on Connectware Manager, see the Connectware
Manager Operator’s Guide, and the Connectware Manager online help.