set alarm
74 Chapter 2 Command Descriptions
ecio_1xrtt
Alarms are triggered when the average Ec/Io 1xRTT signal strength on
a CDMA device falls below a specified threshold for a specified
amount of time. Optionally, a subsequent alarm is triggered when
signal strength returns to the optimal state above the threshold.
ecio_1xevdo
Alarms are triggered when the average Ec/Io 1xEVDO signal strength
on a CDMA device falls below a specified threshold for a specified
amount of time. Optionally, a subsequent alarm is triggered when
signal strength returns to the optimal state above the threshold.
mobile_temp
Alarms are triggered when the mobile temperature goes above a
specified threshold. Optionally, a subsequent alarm is triggered when
signal strength returns to a temperature below the threshold.
1xevdo_unavail
Alarms are triggered when 1xEVDO service is unavailable for a
specified amount of time. Optionally, a subsequent alarm is triggered
when service becomes available again.
mobile_unavail
Alarms are triggered when mobile service is unavailable (not
registered on the home network) for a specified amount of time.
Optionally, a subsequent alarm is triggered when service becomes
available again.
config_change
Alarms are triggered when mobile configuration is changed.
priority={normal|high}
The priority of the triggered email.
normal
The email is sent with normal priority.
high
The email is sent with high priority.
The default is “normal.”
subject=string
If “type=email,” this option specifies the text to be included in the “subject”
field of an alarm-triggered email. If “type=snmptrap,” this option specifies
the text to be included in the “Serial Alarm Subject” field of an alarm-
triggered SNMP trap.
to=string