Epson 100-88002 Printer User Manual


 
Control Codes
100-88002 Rev B Page 133
The following table specifies the Code 39 character set.
A
SCII Code
NUL %U
SOH $
A
STX $B
ETH $C
EOT $D
ENQ $E
A
CK $F
BEL $G
BS $H
HT $I
LF $J
VT $K
FF $L
CR $M
SO $N
SI $O
DLE $P
DC1 $Q
DC2 $R
DC3 $S
DC4 $T
NAK $U
SYN $V
ETB $W
CAN $X
EM $Y
SUB $Z
ESC %
A
FS %B
GS %C
RS %D
US %E
A
SCII Code
SP Space
!
/A
/
B
#
/
C
$
/
D
%
/
E
&
/
F
/
G
(
/
H
)
/
I
*
/
J
+
/
K
,
/
L
- -
. .
/
/
O
0 0
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
9 9
:
/
Z
; %F
< %G
= %H
> %I
? %J
A
SCII Code
@%V
A
A
BB
CC
DD
EE
FF
GG
HH
II
JJ
KK
LL
MM
NN
OO
PP
QQ
RR
SS
TT
UU
VV
WW
XX
YY
ZZ
[%K
\
%L
]%M
^%N
_ %O
A
SCII Code
` %W
a +
A
b +B
c +C
d +D
e +E
f +F
g +G
h +H
i +I
j
+J
k +K
l +L
m +M
n +N
o +O
p +P
q +Q
r +R
s +S
t +T
u +U
v +V
w +W
x +X
y +Y
z +Z
{ %P
| %Q
} %R
~ %S
DEL %T
Figure 28 Code 39 Full 128 Character Encoding
Code 128
Code 128 is an alphanumeric bar code. It is a high-density, variable-length,
continuous code, which employs multiple element widths. Code 128 has three
possible start codes. The start code defines the code set, Code A, B, or C that will be
used to generate the barcode. The Epic 880
TM
allows the code set to be specified, or
it can be select by the printer based on the information in the data field.
To specify code set: [ESC] b <2> <Code>{information} [ETX]
If the first character in the data field <Code> is a start code as shown in Figure 29
below, the printer will print the complete data field from the selected set. Due to space
limitations, only ten characters can be printed. The check digit is generated and
printed by the printer. Characters are also specified as shown in Figure 29.
To have the printer selected code set and automatically generate an optimal barcode,
the value of Code should be the length.
[ESC] b <2> <Length>{information}