Control Codes
100-88002 Rev B Page 149
The resulting journal entry would then only contain:
---{Date:0} {Time:0:}--
ST# 2000 OP# 00067 TE# 021 0035
SUB TOTAL 8.68
SALES TAX 1.50
------
TOTAL 10.18
CASH TEND 20.00
CHANGE DUE 9.82
In carbon copy mode any printer control commands in the record data will be added to
the journal record. As the records are printed, those commands will be used to format
the print. Some care should be taken to assure that only format control command that
you intend to be printed later get in the journal.
Note: Information is gathered in packets or 16 bytes. If power is lost before
the record is closed, up to 16 bytes of information may be lost. The link list