GE ML1600 Switch User Manual


 
17–4 MULTILINK ML1600 ETHERNET COMMUNICATIONS SWITCH – INSTRUCTION MANUAL
ALARM RELAYS CHAPTER 17: MISCELLANEOUS COMMANDS
Example 17-1: Alarm relays
ML1600#
alarm
ML1600(alarm)##
add event=2
Alarm Event(s) Added: 2
ML1600(alarm)## add event=1-5
Event 2 is Already Enabled.
Alarm Event(s) Added: 1, 3, 4, 5
ML1600(alarm)## add event=6,8
Alarm Event(s) Added: 6, 8
ML1600(alarm)## add event=all
Event 1 is Already Enabled.
Event 2 is Already Enabled.
Event 3 is Already Enabled.
Event 4 is Already Enabled.
Event 5 is Already Enabled.
Event 6 is Already Enabled.
Event 8 is Already Enabled.
Alarm Event(s) Added: 7, 9, 10, 11, 12
ML1600(alarm)## del event=2
Alarm Event(s) Deleted: 2
ML1600(alarm)## period time=5
Relay closure Time Set.
ML1600(alarm)## show alarm
Alarm Events Configuration
--------------------------
Alarm Status: DISABLED
Relay Closure Time Period: 5 Seconds
EventId Description Mode
------------------------------------------
1 S-RING OPEN SUSTAINED
2 Cold Start NOT ENABLED
3 Warm Start MOMENTARY
4 Link Up MOMENTARY
5 Link Down MOMENTARY
6 Authentication Failure MOMENTARY
7 RMON Raising Alarm MOMENTARY
8 RMON Falling Alarm MOMENTARY
9 Intruder Alarm MOMENTARY
10 Link Loss Learn Triggered MOMENTARY
11 Broadcast Storm Detected MOMENTARY
12 STP/RSTP Reconfigured MOMENTARY
(continued on next page)