GE ML1600 Switch User Manual


 
CHAPTER 5: IP ADDRESSING SYSTEM CONFIGURATION
MULTILINK ML1600 ETHERNET COMMUNICATIONS SWITCH – INSTRUCTION MANUAL 5–19
FIGURE 5–4: Displaying configuration for different modules.
Note – multiple modules can be specified on the command line
5.4.4 Saving Configuration
It is advisable to save the configuration before updating the software, as it may be
necessary in certain situations. The loadconf command requires a reboot to activate the
new configuration. Without a reboot, the ML1600 used the previous configuration. When
reboot is selected, the user is prompted as follows:
Reboot? ['Y' or 'N']
Select “Y”. The ML1600 will prompt:
Save Current Configuration?
Select “N”.
ML2400# show config module=snmp,system
[HARDWARE]
type= ML2400
slotB=8 Port TP Module
##########################################################
# System Manager - This area configures System related #
# information. #
##########################################################
[SYSTEM]
***Edit below this line only****
system_name=Main
system_contact=someone@joe.com
system_location= Markham, Ontario
boot_mode=manual
system_ip=192.168.1.15
system_subnet=0.0.0.0
system_gateway=192.168.1.11
idle_timeout=10
telnet_access=enable
snmp_access=enable
web_access=enable
--more—
...