Hitachi L100 Power Supply User Manual


 
Restoring Factory Default Settings
Troubleshooting
and Maintenance
6–8
Restoring Factory Default Settings
You can restore all inverter parameters to the original factory (default) settings, for the
intended country of use. After initializing the inverter, use the powerup test in Chapter 2
to get the motor running again. To initialize the inverter, follow the steps below.
1. First, check the value of function code B85. The initialization in step 2 will restore
defaults for the country code programmed in function B85:
00 = Japan (do not set), 01 = Europe, 02 = United States
Please do not change this setting unless you are absolutely sure the power input voltage
range and frequency match the country code setting.
2. Initialization - this uses function code B84. Follow the steps in the table below.
NOTE: Initialization cannot be performed with a remote operator panel. Disconnect the
device and use the inverter’s front panel keypad.
Action Display Func./Parameter
Press the
key.
First “D” group parameter
Press the
key twice.
“B” group selected
Press the
key.
First “B” parameter selected
Press and hold the key until ->
Initialization function selected
Press the
key.
0 = initialization disabled
Press the key.
1 = initialization enabled
Press the key.
Initialization now enabled to
restore all defaults
Press and hold the
, , and
keys. Do not let release yet.
First part of special key sequence
Holding the keys above, press and
hold the
(STOP) key for 3 sec.
Final part of special key sequence
Release only the
(STOP)
key,
and wait for the display
d 01
to
appear and begin blinking.
Initialization begins when display
starts blinking
Now release the
, , and
keys only after the d 01 display
function begins blinking.
or
Default parameter country code
shown during initialization
process (left-most char displays
alternating pattern)
Initialization is complete. Function code for output
frequency monitor shown
FUNC.
01D
2
--B
FUNC.
01B
1
84B
FUNC.
00
1
01
STR
84B
FUNC.
1
2
84B
STOP
STOPSTOP
STOP
RESET
84B
STOP
STOPSTOP
STOP
RESET
01D
FUNC.
1
2
EU
SUA
01D
Technologies Inc.
Toll Free: voice: 1-877-539-2542 fax: 1-800-539-2542 www.mgitech.com