Tests
Calibration of New Paper, Emulsion Changes, or Correction of
a Paper Channel (Not Master Paper)
1. Print an MBL.
This provides for a calibrated condition of the system.
2. Print the PBL right after the MBL:
• With laser point for new papers other than the master paper
or
• Without laser point if there was an emulsion change only
Calibration of New Paper, Emulsion Changes (Master Paper)
1. Print the MBL on the previous (old) emulsion.
This provides for a calibrated condition of the machine.
2. Immediately print a PBL without laser point on the new master paper.
NOTE: If the old emulsion was used up before an MBL could be printed, the
calibration of the new paper can only be started with a PBL calibration.
However, in this case be sure that the equipment is calibrated. Otherwise,
there may be a deviation between the master paper and all other papers. If
this is the case, perform a complete new calibration.
Completion of the New Calibration
If there is too much deviation in the paper styles, a new calibration is recommended.
1. Print an MBL on master paper
2. Immediately print a PBL without laser point for all papers other than the master
paper.
After manipulations on the laser module or after changing the chemicals, a new
calibration is recommended:
1. Print a PBL with laser point on the master paper.
2. Print an MBL.
3. Immediately print a PBL with laser point for all papers other than the master
paper.
KODAK PROFESSIONAL RP 30 Laser Printer 5-9