Kodak RP 30 Printer User Manual


 
Operator’s Guide
Emptying the Effluent Tanks
WARNING:
NOTE:
Wear protective gloves, a rubber apron, and goggles when you
empty the effluent tanks.
As soon as one of the effluent tanks is full, a message appears on the screen
advising that this tank must be emptied.
It is possible to touch Clear to suppress the message and to continue the
work for a while. When the message appears for the third time, it can no
longer be cleared.
Empty the full tank:
1. Open the front door at the bottom left of the paper processor. Position (1) marks
the drain valves to be opened to empty the effluent tanks.
2. Put a bucket under the respective drain valve. Open the valve and empty the
tank. Close the valve.
Perform the same procedure with the adjacent second valve.
CAUTION:
IMPORTANT:
Do not open both valves at the same time. The volume of both
tanks is 20 L.
Do not open the drain valves in the vertical position on the right
side. They are used to empty the processing tanks CD, BX and
SB1 to SB4, for example, when a completely new tank preparation
has to be filled into single or all tanks.
Check the pan (2): If it is full although the customer emptied the
tanks always in time, a technician must be called. The hose
systems could be defective.
8-38 KODAK PROFESSIONAL RP 30 Laser Printer