188 NT5D11 and NT5D14 Lineside T1 Interface cards
Table 85
Lineside T1 card - environmental specifications
Parameter
Specifications
Operating temperature-normal
15
to +30 C (+59 to 86 F), ambient
Operating temperature-short term
10
to +45 C (+50 to 113 F), ambient
Operating humidity-normal 20% to 55% RH (non-condensing)
Operating humidity-short term 20% to 80% RH (non-condensing)
Storage temperature
–50
to +70 C (–58 to 158 F), ambient
Storage humidity 5% to 95% RH (non-condensing)
Table 86 "Lineside T1 card - environmental specifications" (page 188) lists
the environmental specifications of the Lineside T1 card.
Table 86
Lineside T1 card - environmental specifications
Parameter
Specifications
Operating temperature-normal
15
to +30 C (+59
to 86 F), ambient
Operating temperature-short term
10
to +45
C (+50 to 113
F), ambient
Operating humidity-normal 20% to 55% RH (non-condensing)
Operating humidity-short term 20% to 80% RH (non-condensing)
Storage temperature
–50
to +70 C (–58 to 158 F), ambient
Storage humidity 5% to 95% RH (non-condensing)
Installation and configuration
Installation and configuration of the Lineside T1 card consists of six basic
steps:
Step Action
1
Configure the dip switches on the Lineside T1 card for the
environment.
2
Install the Lineside T1 card into the selected card slots in the IPE
shelf.
3
Cable from the I/O panel to the Customer Premise Equipment
(CPE) or CSU, MMI terminal or modem (optional), external alarm
(optional), and other Lineside T1 cards for daisy chaining use of
MMI terminal (optional).
4
Configure the MMI terminal.