Man-Machine T1 maintenance interface software 231
LTI:ss cc> for multi-card installations, where ss represents the
two-digit address, and cc represents the two-digit card slot address
Basic commands
MMI commands can now be executed. There are seven basic commands
that can be combined together to form a total of 19 command sets. They are:
Alarm
Clear
Display
Set
Test
Help
Quit
If ?<CR> is typed, the MMI lists the above commands along with an
explanation of their usage. A screen similar to the following appears. The
help screen also appears by typing H<CR>,orHELP<CR>.
ALARM USAGE: Alarm [Enable | Disable]
CLEAR USAGE: Clear [Alarm] | [Error counter] [Log]
DISPLAY USAGE: Display [Alarm | Status | Perform |
History] [Pause]
HELP USAGE: Help | ?
SET USAGE: Set [Time | Date | Alarm | Clearing |
Name | Memory]
TEST USAGE: Test [Carrier All]
QUIT USAGE: Quit
Notation Used:
CAPS - Required Letters [ ] - | - Either/
Optional Or
Each of these commands can be executed by typing the first letter of the
command or by typing the entire command. Command sets are entered
by typing the first letter of the first command, a space, and the first letter
of the second command or by typing the entire command. Table 103 "MMI
commands and command sets" (page 231) shows all the possible command
sets, listed in alphabetical order. These commands are described by subject
later in this section.
Table 103
MMI commands and command sets
Command
Description
AD
Alarm Disable
Disables all alarms.