198 NT5D11 and NT5D14 Lineside T1 Interface cards
XPEC
Address
S1 Switch
Position 3
S1 Switch
Position 4
S1 Switch
Position 5
S1 Switch
Position 6
07
Off On On On
08
On Off Off Off
09
On Off Off On
10
On Off On Off
11
On Off On On
12
On On Off Off
13
On On Off On
14
On On On Off
15
On On On On
Table 93
Lineside T1 card - T1 Switch 2 (S2) dip switch settings
Dip Switch
Number Characteristic Selection
1
T1 framing On = D4
Off = ESF
2
T1 Coding On = AMI
Off = B8ZS
3–5
CPE or CSU distance See Table 94 "Lineside T1 card -
CPE or CSU distance dip switch
settings (Switch S2, positions 3
- 5)" (page 198)
6
Line processing on T1 link failure On = On-hook
Off = Off-hook
7
Daisy-chaining to MMI On = Yes
Off = No
8
MMI Master or Slave On = Master
Off = Slave
Table 94
Lineside T1 card - CPE or CSU distance dip switch settings (Switch S2, positions 3 - 5)
Distance
S2 Switch
Position 3
S2 Switch
Position 4
S2 Switch
Position 5
0–133
On Off Off
134–266
Off On On
267–399
Off On Off
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 01.04 Standard
Release 5.0 23 May 2008
Copyright © 2003-2008, Nortel Networks
.