948 NTAK79 2.0 Mb PRI card
If the incoming reference is unstable, the inter nal clock controller remains
continuously in the tracking stage with the LED flashing green all the time.
This condition does not present a problem, rather, it shows that the clock
controller is continually attempting to lock onto the signal. If slips are
occurring, however, it means that there is a problem with the clock controller
or the incoming line.
Free-run (non-tracking) In free-run mode, the clock controller does not
synchronize on any source, it provides its own internal clock to the system.
This mode can be used when the Option 11C is used as a master clock
source for other systems in the network. Free-run mode is undesirable if
the Option 11C is intended to be a slave. It can occur, however, when both
the primary and secondary clock sources are lost due to hardware faults
or when invoked by using software commands.
Clock controller functions and features
The NTAK79 clock controller functions and features include:
phase lock to a reference, generate the 10.24 MHz system clock, and
distribute it to the CPU through the backplane. Up to two references at
a time are accepted
primar y to secondary switchover (auto-recovery is provided)
prevent chatter
error burst detection and correction, holdover, and free running
capabilities
compliance with 2.0Mb CCITT specifications
software communication
jitter filtering
use of an algorithm to detect crystal aging and to qualify clocking
information
The NTAK79 clock controller functions and features include:
phase lock to a reference, generate the 10.24 Mhz system clock, and
distribute it to the CPU through the backplane. Up to two references at
a time may be accepted.
provide primary to secondary switchover (auto-recovery is provided)
prevent chatter
provide error burst detection and correction, holdover, and free running
capabilities
comply with 2.0Mb CCITT specifications
communicate with software